There is a broad range of mechanical design options available for meeting the heating and cooling needs of residential buildings. Normally, these systems differ in terms of the medium used to deliver their heating or cooling output.
This article will provide an overview of some of the most common mechanical design options used for indoor residential spaces, as well as the strengths and limitations of each type of system:
HVAC System | Heating/Cooling Medium |
---|---|
1) Four-Pipe System with Chiller, Cooling Tower, & Boiler 2) Water-Source Heat Pump with Cooling Tower & Boiler 3) VRF System with Rooftop Condensers & Gas Boiler 4) PTAC Unit with Electric Resitance Heating |
Water Piping Water Piping Refrigerant Piping Direct |
This mechanical design gets its name from the fact that it has two separate water circuits, one carrying hot water and another carrying chilled water, each with a supply and return pipe. The basic operating principle of four-pipe systems is the following:
The main advantage of four-pipe systems is their ability to use both modes of operation simultaneously and independently. This can be especially useful if heating and cooling needs are different across building zones, and especially in apartment buildings and multi-family dwellings where preferences and schedules normally vary by occupant. Of course, a four-pipe system is expensive to install due to the presence of three separate water circuits: two for the distribution of cold and hot water, and a third one used by the chiller to reject heat through the cooling tower.
A heat pump can be described in simple terms as a reversible air conditioner: it can deliver indoor cooling through the refrigeration cycle, but can also operate in heating mode with a much higher efficiency than most types of boilers, especially electrical resistance boilers.
Due to their reversible operation, water-source heat pumps offer great flexibility in residential buildings. Individual units can be set to operate in different modes, and in combined heating and cooling applications the overall system can be extremely efficient:
The fact that heat pumps share the same water circuit means that the cooling tower and boiler only have to balance system loads, rather than meeting them fully:
A four-pipe system lacks these capabilities: the chiller must assume the full cooling load while the boiler provides the full heating load – all the heat absorbed in the chilled water loop is rejected by the cooling tower, and can’t be used for space heating purposes because water circuits are independent.
HVAC systems based on water-source heat pumps are extremely efficient, although expensive due to the fact that every zone must be equipped with an individual heat pump, in addition to having a common water circuit, a cooling tower, and a boiler.
VRF stands for variable refrigerant flow, and VRF systems get their name from the fact that refrigerant is used to transport heat instead of water:
Other than operational flexibility, an advantage of this mechanical design option is their ease of installation: refrigerant lines are more compact than water piping and air ducts. These systems still have a relatively small market share in the USA, but are very common in Japan, where they were developed, and Europe. According to ASHRAE, VRF systems tend to have a comparable cost to that of chiller-based systems, potentially higher if the technology must be imported.
The modular nature of VRF systems is another strong point in favor of this technology. If there will be a building expansion, it is possible to expand the system by simply adding a new condenser and the corresponding indoor evaporators.
Packaged terminal air conditioning units (PTAC) are compact systems, very similar to old window-type air conditioners: the system is self-contained and does not require refrigerant lines, water piping, or air ducts, greatly reducing the installed cost. Some PTAC units are equipped with a resistance heater, allowing them to operate in both heating and cooling modes.
PTAC units offer the advantage of being self-contained and independent from each other. This gives them an advantage in projects that will be built in several stages, for example, apartment buildings, since it is possible to expand HVAC capacity as needed without having a common system on which all units depend.
The main limitation of this mechanical system is that they tend to be outclassed by other systems in terms of efficiency, especially when in heating mode. Resistance heating offers a coefficient of performance of 1.0, which means they must draw one watt of electricity per each watt of heating; on the other hand, heat pumps typically operate with a COP of 2.5 or more, or even above 4.0 if a high-efficiency heat pump is selected.
There is a broad range of heating and cooling technologies available for residential buildings, and also a high degree of flexibility in how the overall system can be configured. No system can be considered superior to the rest under all circumstances – every project offers unique conditions that favor some technologies over others.
What kind of mechanical design has worked the best for you? Let us know by commenting below. If you would like further assistance choosing the best HVAC system for you, click here to learn about our mechanical engineering services.