<img height="1" width="1" style="display:none;" alt="" src="https://px.ads.linkedin.com/collect/?pid=5133266&amp;fmt=gif">
Local Law 26

Local Law 26 of 2004 made automatic sprinklers mandatory for many properties in New York City, including high-rise office buildings. LL26/04 was published in response to the 9/11 incident, with the goal of making buildings more resistant to fire. Nearby Engineers has ample experience designing sprinkler systems according to NYC building codes and Local Law 26. This ensures a quick project approval.

Need help?

Keith Fink

Principal

(786) 788-0295

inquiry@ny-engineers.com

Get In Touch

Why Choose Us?

We are one of the fastest growing MEP design firms in the construction industry. We pride ourselves on having a fast turnaround while providing cost effective solutions. We are licensed in 50 states and are your one stop shop for all MEP design needs.

0

States

We are licensed in all 50 states!

0

Errors

We design to the perfection

0

Days

Enjoy our lightening fast turnaround

0

Projects

We have completed so far!

0

First Time Approval

Our designs are approved by DOB in one go

0

Repeat Customers

The best service experience in the market

Get Pricing On a New MEP Design Proposal in Fewer than 24 Hours

Request a proposal

What Is Local Law 26 of 2004?

Local Law 26 of 2004 made automatic sprinklers mandatory for many properties in New York City, including high-rise office buildings. LL26/04 was published in response to the 9/11 incident, with the goal of making buildings more resistant to fire.

LL26 introduced many fire protection measures, but the most demanding requirement was making fire sprinklers mandatory for many existing buildings. Since installing sprinklers in a large building is a considerable investment, LL26 provided a 15-year deadline. All buildings covered by the law were required to have automatic sprinklers by July 1, 2019.

The NYC Department of Buildings published a Summary of Provisions for Local Law 26 of 2004. There are prospective requirements that only affect new constructions, and retroactive requirements that affect existing buildings as well - installing fire sprinklers was among the retroactive requirements.

Does Local Law 26 of 2004 Affect My Building?

Local Law 26 does not mandate the installation of fire sprinklers for all properties in NYC. The measure is only required in buildings that meet both of the following conditions:

  • Buildings classified under occupancy Group E (business), based on the occupancy definitions from 2004.
  • Buildings that are at least 100 feet tall.

Note that occupancy groups have been redefined since 2004. Group E now refers to education, which is different from the Group E defined in LL26. However, automatic sprinklers are recommended even in buildings where they are not mandatory. In addition to providing effective fire protection, sprinklers make buildings eligible for better insurance plans.

Understanding How Automatic Sprinklers Work

There is a common misconception that fire sprinklers shower an entire building with water at the first sign of smoke or fire. This wrong idea has been spread by movies and TV series, but it can make building owners skeptical about installing fire sprinklers. In real-life applications, many fires are stopped by a single sprinkler head.

  • Automatic sprinklers respond to heat, and they open when the hot air produced by fire reaches them. As a result, only sprinklers that are directly above the fire release water.
  • Fire sprinklers do not open with smoke, only heat. Smoke by itself will just trigger alarms.

Deluge-type sprinkler systems work like those in the movies, releasing water over an entire area when fire or smoke are detected. However, these sprinkler systems are only used in fire-sensitive applications, not in commercial buildings.

How Much Does an Automatic Sprinkler System Cost?

An automatic sprinkler system can cost up to $10 per square foot of building area. However, the project cost can be reduced with an optimal sprinkler head layout and smart design decisions. In new projects, fire protection engineers can collaborate with architects and interior designers to achieve full coverage of your building with the smallest possible number of sprinkler heads.

Fire sprinklers offer benefits for building owners, even if the property never suffers a fire incident in its entire service life. As previously mentioned, buildings become eligible for better insurance plans when they are equipped with automatic sprinklers. Effective fire protection systems also provide a marketing advantage for real estate developers - the additional safety can help convince a potential tenant to sign a lease.

Who Can Design And Install Fire Sprinkler Systems In NYC?

Before proceeding with a fire sprinkler installation, consider the following requirements:

  • Only a Registered Design Professional (RDP) can get the sprinkler system design approved with the NYC Department of Buildings. The RDP can be either a Registered Architect (RA) or a Professional Engineer (PE).
  • After the sprinkler system design is approved by the NYC DOB, only a Licensed Master Plumber (LMP) or Licensed Fire Suppression Contractor (LFSC) can carry out the installation.

has ample experience designing sprinkler systems according to NYC building codes and Local Law 26. This ensures a quick project approval.

When Does LL26 Require an Emergency Action Plan (EAP)?

The New York City Fire Department (FDNY) provides the following definition of an Emergency Action Plan:

“A written plan which sets forth the circumstances and procedures for the sheltering in place, in-building relocation, partial evacuation or evacuation of building occupants in response to an emergency.” 

Local Law 26 of 2004 requires an Emergency Action Plan for buildings under the Business Group E classification, as defined in 2004, if they meet any of the following conditions:

  • Buildings above six stories high.
  • Buildings taller than 75 feet.
  • Occupant load of more than 100 above or below the street level.
  • Occupant load of more than 500 in the entire building.
  • Special cases where the building is required to have a fire safety director according to the NYC Administrative Code.

There are also special cases where the NYC Department of Buildings requires an Emergency Action Plan for public safety reasons, even if the building does not meet the conditions above.